Wiring diagram 5
Terminal diagram IG/IZ38-30-I
Electrical connection / control
Types C + D with control unit IG/IZ38-30-I
Fig. 5
Description
For control of intermittently operated single-line centralized lubrica-
tion systems, the compact pump units with 3 or 6 liter reservoirs
can be fitted with an electronic control unit.
Either:
• IG38-30-I, timer operation for
time-dependent control
1)
• IZ38-30-I, counter operation for
load-dependent control
2)
Functions
• Adjustable interval duration
• Non-adjustable pump dwell time
• Non-adjustable pressure build-up monitoring time
• Pump run time limitation
• Prelubrication (lubrication when the supply voltage is switched on)
• Fill level monitoring with detection of wire
breakage (WS switch contact opens when level is too low)
• Operation with 3-wire proximity switch possible
Preset parameters
IG38-30-I
• Interval time 1 minute (for time-dependent control)
• Monitoring time 60 seconds
• Pump dwell time 15 seconds
IZ38-30-I
• Interval time 1 pulse (for load-dependent control)
• Monitoring time 60 seconds
• Pump dwell time 15 seconds
Lubrication interval duration
1)
In minutes
2)
In number of pulses of the external machine contact MK
3)
Machine contact MK only required with counter
operation
(IZ38-30-I).
4)
Control unit can be set to either 230 V AC or 115 V AC.
The pump motor's voltage setting cannot be changed.
d2: 12 malfunction
d
2: 24 normal operation
d
2: 22 malfunction
16